Universal columns vs universal beams: what is the difference?
If you have ever looked at a structural steel specification and wondered why some sections are labelled UC and others UB, you are not alone. The two terms are easy to confuse, and the difference is not always explained clearly on site or in college. This guide breaks down what each section is, how to tell them apart, and when you would use one instead of the other.
What is a universal beam?
A universal beam, abbreviated to UB, is the section most people picture when they think of a steel beam. It has an I-shaped cross-section, with two horizontal flanges connected by a vertical web. The flanges on a UB are narrower relative to the overall depth of the section, which means the beam is significantly deeper than it is wide.
This shape is specifically designed to resist bending. When a load is applied across a horizontal span, the top flange is put into compression and the bottom flange is put into tension. The deep web between them creates the lever arm that makes the section efficient at carrying that bending load. This is why UBs are the go-to section for floor beams, roof beams, lintels, and anywhere a horizontal span needs to carry load from above.
Universal beams are what most builders are referring to when they talk about RSJs, though strictly speaking RSJ (rolled steel joist) is an older section type that has largely been replaced by the UB in modern construction.
What is a universal column?
A universal column, abbreviated to UC, has the same I-shaped cross-section as a universal beam, but the proportions are different. In a UC, the flanges are much wider relative to the depth of the section, making it appear more square-on when viewed from the end. The flanges are also thicker than those on a comparable UB.
This shape is designed to resist compression rather than bending. When a vertical load pushes straight down through a column, the section needs to resist buckling rather than bending. The wide, thick flanges of a UC make it much better at this than a UB would be in the same situation.
Universal columns are used as vertical supports: stanchions in steel frames, posts carrying a beam above, columns in portal frames, and anywhere a section needs to carry a predominantly axial (vertical) load rather than a spanning (horizontal) one.
How do you read the section reference?
Both UBs and UCs are described using a standard notation that tells you the depth, width, and mass per metre of the section. For example:
A 203 x 203 x 46 UC is a universal column that is 203mm deep, 203mm wide, and weighs 46 kilograms per metre of length.
A 254 x 146 x 37 UB is a universal beam that is 254mm deep, 146mm wide, and weighs 37 kilograms per metre of length.
You will notice that the UC dimensions are nearly equal in depth and width, giving it that square appearance. The UB dimensions show a section that is significantly deeper than it is wide.
Can you use a UC as a beam or a UB as a column?
Technically yes, and it does happen in practice, but only on the advice of a structural engineer. A UC used horizontally as a beam will carry some bending load, but it is less efficient at it than a UB of comparable weight because of its proportions. Equally, a UB can be used vertically as a column in some situations, but its narrower flanges make it more susceptible to buckling under heavy axial loads.
Your structural engineer will specify which section is appropriate for the application. If a drawing calls for a UC, do not substitute a UB of similar size without going back to the engineer, even if the two sections look interchangeable on paper.
Common mistakes on site
The most frequent confusion arises when builders order steel from a description rather than a drawing. Asking for “a 203 by 203” without specifying UC or UB will cause problems, because a 203 x 203 UC and a 203 x 203 UB are very different sections with different properties. Always use the full section reference from your structural engineer’s drawing when placing an order.
It is also worth checking the orientation on the drawing. Universal beams and columns are both installed with the web vertical as standard, but there are situations where a beam is rotated 90 degrees (laid on its side) for specific loading or depth reasons. If in doubt, check with your engineer before the steel arrives on site.
Ordering from Builders Beams R Us
Whether your project calls for universal beams, universal columns, or bespoke fabricated sections, we can supply and cut to your exact specification from our Wakefield facility.
Send us your drawings or section reference and we will get a price back to you quickly.